Electrical & Power: Beginner CFD Training Package — Ep 03
IGBT Heat Sink Cooling
- Lesson
- 03
- Run Time
- 19m 28s
- Published
- Jul 31, 2026
- Category
- Electrical & Power
- Course Progress
- 0%
IGBT Heat Sink Cooling CFD Simulation, ANSYS Fluent Training
Description
This project simulates the cooling of an IGBT heat sink using ANSYS Fluent. An insulated-gate bipolar transistor (IGBT) is a three-terminal power semiconductor device, widely used as an electronic switch in inverters, motor drives, and power converters. During operation, IGBTs generate considerable thermal energy, and excessive heat directly degrades their performance and lifespan. Applying an effective cooling strategy — such as an air- or liquid-cooled heat sink — dissipates this surplus heat, enabling higher power densities, better performance, and more compact module designs.
In this simulation, the heat sink is in contact with a heat source applying a flux of 14,583 W/m² on one surface, while air flows across the opposite surface at a mass flow rate of 0.25 kg/s, serving as the primary cooling mechanism for the assembly.
Methodology
The simulation geometry includes both the heat source and the heat sink. The model is designed and meshed in Gambit® software, using an unstructured grid with a total of 11,872,367 elements to resolve the details of the flow and thermal fields.
The energy equation is activated to model the heat transfer between the heat source, the heat sink body, and the cooling airflow. Given the flow conditions in this configuration, the laminar viscous model is applied to resolve the airflow characteristics throughout the system.
Analysis
At the end of the solution process, temperature distributions, velocity profiles, surface heat flux patterns, and Nusselt number contours are extracted and examined. The results clearly demonstrate how the cooler airflow reduces the temperature of the heat sink as it passes over its surface.
The thermal exchange between the cold air stream and the heat source successfully lowers the overall system temperature, confirming that the cooling mechanism achieves the project's objective. The simulation validates the effectiveness of the selected air-cooling approach for IGBT thermal management — a directly applicable result for power electronics design, where reliable heat dissipation determines both the power rating and the physical size of the module. By completing this project, you will learn to apply a surface heat flux boundary condition, model laminar convective cooling, and evaluate heat sink performance through temperature, heat flux, and Nusselt number analysis.